XS Check

RiverReachRSStrucLen LobLen ChlLen RobTopwdthActQ TotalFlow Code
ELKRNMain14790 309.3309.3309.3102.28468C,IR
  14480 289.1289.1289.187.87468C,IL
  14191 222.1222.1222.193.77468 
  13969 120.6120.6120.646.87468 
  13848 133.7133.7133.781.66468C
  13715 270.2270.2270.2124.63468ER
  13445 418.7418.7418.759.81468IR
  13026 350.1350.1350.197.8468 
  12676 439.4439.4439.447.48468C,IL,IR
  12236 151.4151.4151.4139.37468C
  12085 282.2282.2282.2112.64468 
  11803 199.6199.6199.689.4468IR
  11603 384.3384.3384.390.44468IR
  11219 375.1375.1375.1164.41468 
  10844 213.7213.7213.7132.84468 
  10630 329.1329.1329.1134.32468IR
  10301 347.9347.9347.9103.73468IR
  9953 392.4392.4392.4132.93468 
  9561 173173173138.27468 
  9388 286.7286.7286.7109.34468 
  9101 398.1398.1398.195.92468 
  8703 305.4305.4305.487.63565IR
  8397 351351351113.78565IL
  8046 416.6416.6416.6115.79565IR
  7630 306.1306.1306.167.52565IL,IR
  7324 289.8289.8289.879.29565C,IL
  7034 279.4279.4279.4102.74565IL
  6755 170.8170.8170.8100.33565C
  6584 217.6217.6217.697.43565IR
  6366 357.7357.7357.7102.8565IR
  6008 275.2275.2275.297.83565 
  5733 306.6306.6306.6107.9565 
  5427 381.7381.7381.7127.89565 
  5045 266.9266.9266.990.88628ER,IL
  4778 282.1282.1282.162.23628IR
  4496 168.9168.9168.990.13628 
  4327 191.6191.6191.688.59628 
  4135 241.1241.1241.176.42628 
  3894 410.3410.3410.360.12628IL
  3484 279.6279.6279.681.88628 
  3205 253.7253.7253.792.29628IL
  2951 316.9316.9316.981.78628IR
  2634 319.4319.4319.467.16628 
  2314 251.7251.7251.790.23628 
  2063 261.8261.8261.890.25628 
  1801 278.8278.8278.857.83628IR
  1522 175.4175.4175.480.3628IR
  1347 328.4328.4328.457.76628IR
  1018 212.6212.6212.691.69628 
  806 225.3225.3225.3114.34628 
  580 110.3110.3110.376.65628 
  470 126.8126.8126.893.3628C
  343 120.4120.4120.4100.75628 
  223 57.757.757.784.5628C,IL
  165    92.79628IL

BL = block obstruction left
MBL = multiple block obstructions left
BR = block obstruction right
MBR = multiple block obstruction right
C = critical depth
DL = divided flow left
DR = divided flow right
EL = extended cross section left
ER = extended cross section right
IL = Ineffective station left
MIL = multiple ineffective stations left
IR = ineffective station right
MIR = multiple ineffective stations right

XS CD 01 SECNO: 14790

Critical Depth occurs at 1%-annual-chance flood. Flow Code will be "C". The Ineffective flow option is used. The Ineffective Flow elevation is equal to or higher than the Critical WSEL. Please investigate whether this selection is appropriate.

XS CD 01 SECNO: 14480

Critical Depth occurs at 1%-annual-chance flood. Flow Code will be "C". The Ineffective flow option is used. The Ineffective Flow elevation is equal to or higher than the Critical WSEL. Please investigate whether this selection is appropriate.

XS CD 01 SECNO: 12676

Critical Depth occurs at 1%-annual-chance flood. Flow Code will be "C". The Ineffective flow option is used. The Ineffective Flow elevation is equal to or higher than the Critical WSEL. Please investigate whether this selection is appropriate.

XS CD 01 SECNO: 7324

Critical Depth occurs at 1%-annual-chance flood. Flow Code will be "C". The Ineffective flow option is used. The Ineffective Flow elevation is equal to or higher than the Critical WSEL. Please investigate whether this selection is appropriate.

XS CD 01 SECNO: 223

Critical Depth occurs at 1%-annual-chance flood. Flow Code will be "C". The Ineffective flow option is used. The Ineffective Flow elevation is equal to or higher than the Critical WSEL. Please investigate whether this selection is appropriate.

XS IF 01L SECNO: 14480

Flow code will be IL. The area left of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3473.89 is higher than the ground elevation 3472.642 of the Left Ineffective Flow Station. However, it is equal to or lower than the left ineffective flow elevation of 3479.01. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area left of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area left of the ineffective flow station is non conveyance.

XS IF 01L SECNO: 12676

Flow code will be IL. The area left of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3448.3 is higher than the ground elevation 3447.988 of the Left Ineffective Flow Station. However, it is equal to or lower than the left ineffective flow elevation of 3451.44. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area left of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area left of the ineffective flow station is non conveyance.

XS IF 01L SECNO: 8397

Flow code will be IL. The area left of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3400.73 is higher than the ground elevation 3400.537 of the Left Ineffective Flow Station. However, it is equal to or lower than the left ineffective flow elevation of 3403.29. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area left of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area left of the ineffective flow station is non conveyance.

XS IF 01L SECNO: 7034

Flow code will be IL. The area left of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3380.48 is higher than the ground elevation 3379.2 of the Left Ineffective Flow Station. However, it is equal to or lower than the left ineffective flow elevation of 3383.57. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area left of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area left of the ineffective flow station is non conveyance.

XS IF 01L SECNO: 5045

Flow code will be IL. The area left of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3365.49 is higher than the ground elevation 3365.304 of the Left Ineffective Flow Station. However, it is equal to or lower than the left ineffective flow elevation of 3367.35. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area left of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area left of the ineffective flow station is non conveyance.

XS IF 01L SECNO: 3894

Flow code will be IL. The area left of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3357.32 is higher than the ground elevation 3354.385 of the Left Ineffective Flow Station. However, it is equal to or lower than the left ineffective flow elevation of 3361.43. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area left of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area left of the ineffective flow station is non conveyance.

XS IF 01L SECNO: 3205

Flow code will be IL. The area left of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3353.95 is higher than the ground elevation 3352.18 of the Left Ineffective Flow Station. However, it is equal to or lower than the left ineffective flow elevation of 3357.16. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area left of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area left of the ineffective flow station is non conveyance.

XS IF 01L SECNO: 223

Flow code will be IL. The area left of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3329.49 is higher than the ground elevation 3328.183 of the Left Ineffective Flow Station. However, it is equal to or lower than the left ineffective flow elevation of 3331.75. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area left of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area left of the ineffective flow station is non conveyance.

XS IF 01L SECNO: 165

Flow code will be IL. The area left of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3328.92 is higher than the ground elevation 3326.945 of the Left Ineffective Flow Station. However, it is equal to or lower than the left ineffective flow elevation of 3330.68. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area left of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area left of the ineffective flow station is non conveyance.

XS IF 01R SECNO: 14790

Flow code will be IR. The area to the right of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3483.36 is higher than the ground elevation 3483.353 of the Right Ineffective Flow Station. However, it is equal to or lower than the right ineffective flow elevation of 3485.89. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area right of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area right of the ineffective flow station is non conveyance.

XS IF 01R SECNO: 13445

Flow code will be IR. The area to the right of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3456.74 is higher than the ground elevation 3455.678 of the Right Ineffective Flow Station. However, it is equal to or lower than the right ineffective flow elevation of 3459.86. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area right of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area right of the ineffective flow station is non conveyance.

XS IF 01R SECNO: 12676

Flow code will be IR. The area to the right of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3448.3 is higher than the ground elevation 3447.436 of the Right Ineffective Flow Station. However, it is equal to or lower than the right ineffective flow elevation of 3454.05. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area right of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area right of the ineffective flow station is non conveyance.

XS IF 01R SECNO: 11803

Flow code will be IR. The area to the right of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3438.82 is higher than the ground elevation 3438.69 of the Right Ineffective Flow Station. However, it is equal to or lower than the right ineffective flow elevation of 3440.75. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area right of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area right of the ineffective flow station is non conveyance.

XS IF 01R SECNO: 11603

Flow code will be IR. The area to the right of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3436.61 is higher than the ground elevation 3436.424 of the Right Ineffective Flow Station. However, it is equal to or lower than the right ineffective flow elevation of 3438.71. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area right of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area right of the ineffective flow station is non conveyance.

XS IF 01R SECNO: 10630

Flow code will be IR. The area to the right of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3425.45 is higher than the ground elevation 3424.78 of the Right Ineffective Flow Station. However, it is equal to or lower than the right ineffective flow elevation of 3427.76. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area right of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area right of the ineffective flow station is non conveyance.

XS IF 01R SECNO: 10301

Flow code will be IR. The area to the right of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3422.57 is higher than the ground elevation 3420.492 of the Right Ineffective Flow Station. However, it is equal to or lower than the right ineffective flow elevation of 3423.63. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area right of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area right of the ineffective flow station is non conveyance.

XS IF 01R SECNO: 8703

Flow code will be IR. The area to the right of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3404.56 is higher than the ground elevation 3402.931 of the Right Ineffective Flow Station. However, it is equal to or lower than the right ineffective flow elevation of 3407.73. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area right of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area right of the ineffective flow station is non conveyance.

XS IF 01R SECNO: 8046

Flow code will be IR. The area to the right of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3396.86 is higher than the ground elevation 3394.916 of the Right Ineffective Flow Station. However, it is equal to or lower than the right ineffective flow elevation of 3400.59. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area right of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area right of the ineffective flow station is non conveyance.

XS IF 01R SECNO: 7630

Flow code will be IR. The area to the right of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3390.81 is higher than the ground elevation 3390.597 of the Right Ineffective Flow Station. However, it is equal to or lower than the right ineffective flow elevation of 3399.3. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area right of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area right of the ineffective flow station is non conveyance.

XS IF 01R SECNO: 4778

Flow code will be IR. The area to the right of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3364 is higher than the ground elevation 3362.215 of the Right Ineffective Flow Station. However, it is equal to or lower than the right ineffective flow elevation of 3373.22. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area right of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area right of the ineffective flow station is non conveyance.

XS IF 01R SECNO: 2951

Flow code will be IR. The area to the right of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3351.78 is higher than the ground elevation 3350.236 of the Right Ineffective Flow Station. However, it is equal to or lower than the right ineffective flow elevation of 3357.51. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area right of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area right of the ineffective flow station is non conveyance.

XS IF 01R SECNO: 1522

Flow code will be IR. The area to the right of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3342.48 is higher than the ground elevation 3341.89 of the Right Ineffective Flow Station. However, it is equal to or lower than the right ineffective flow elevation of 3345.45. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area right of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area right of the ineffective flow station is non conveyance.

XS IF 01R SECNO: 1347

Flow code will be IR. The area to the right of the ineffective flow station may be considered effective. The 1%-annual-chance WSEL of 3341.01 is higher than the ground elevation 3338.711 of the Right Ineffective Flow Station. However, it is equal to or lower than the right ineffective flow elevation of 3343.57. The lateral structure was not modeled downstream of this River Station. Lower the ineffective flow elevation to the ground elevation to consider the area right of the ineffective flow station as effective, or model a lateral structure if the overflow will take a different flow path. The ineffective flow elevation could be accepted if the area right of the ineffective flow station is non conveyance.